4 publications
-
Published Subscription
Mocking up of Thermal Power Plant for Better understanding of Load Frequency ControlBy shivank shukla
Abstract: The integrated power system consists of control areas linked by tie lines to each other. The loads of the generator, station, and device are determined by the summation of different outputs of the thermal converter. Frequency is determined by the instrument form of the frequency bridge. Because this data is fed into a master controller, it can sense the need for more or less generation and send impulses to the …
Published in International Journal of Power Electronics Controllers and Converters · Vol. 5, Issue 2, 2019 · pp. 9–18 Read article →
-
Published Subscription
A Review on Two-Area Hydro-thermal Power SystemBy shivank shukla
Abstract: In a two-area system, there will be one automatic load frequency control (ALFC) loop for each control area. Practical aspects considered in this system are reheat turbine in thermal power plant and mechanical governor in hydro-power plant. Reheat turbine improves the efficiency of the system as it again utilizes the steam coming out from high pressure turbine (HP) to run the intermediate pressure (IP) turbine and low pressure (LP) turbine.Keywords: …
Published in International Journal of Power Electronics Controllers and Converters · Vol. 5, Issue 2, 2019 · pp. 30–40 Read article →
-
Published Subscription
A Review on Multi-Area Load Frequency ControlBy shivank shukla
Abstract: The operation of interconnected deregulated power system is totally based upon the balance between power generation and the load variation including system losses. Two variables of interest which are affected due to the sudden variation in load perturbation are system frequency and tie-line power. The approach of most of the researchers towards solving this problem has been to obtain the best method of controlling the governor action so that the …
Published in International Journal of Analog Integrated Circuits · Vol. 5, Issue 2, 2019 · pp. 21–39 Read article →
-
Published Subscription
Analysis of AGC simulation model using SIMULINKBy shivank shukla
Abstract: A Simulation model is developed and it is analyzed using SIMULINK as well as well as state space model. The system is investigated without controller, using conventional integral controller, conventional PI controller, BFO integral controller. The performance of the system is analyzed by consideration frequency, tie-line power and power generated by GENCOs. Keywords: SIMULINK GENCO, Bacterial Foraging Optimization, ACE, PI Controllor, DISCO, space state, AGC
Published in International Journal of Analog Integrated Circuits · Vol. 5, Issue 2, 2019 · pp. 46–57 Read article →